Protocol timeout: Click in “Protocol timeout” text box and type a period of Protocol timeout
assigned to the serial port on the Serial Device Server. The connection will be closed and the
port will be freed for connection with other hosts when serial port stops data transmission for a
defined period of time (Protocol timeout). The default Protocol timeout is 0ms.
Step 4: Data Packing
Delimiter1, 2: Check this option to enable Delimiter1, 2. Click in Delimiter1, 2text box and
Delimiter1, 2 assigned to the serial port on the Serial Device Server. The data will be
transmitted if the Delimiter1 is received or Delimiter1 and Delimiter2 are received.
Force transmit: Click in “Force transmit” text box and specify Force transmit to the serial port
on the Serial Device Server. The data will be transmitted when the Force transmit is reached.
The default Force transmit of the serial port is 0 to disable Force transmit.
Step 5: UDP Network settings
Server 1 ~ 8: Click in “Server 1 ~ 8” text boxes to specify IP addresses and Port numbers of
remote UDP Servers.
UDP Port: Click in “UDP Port” text box and type a UDP Port number assigned to the Source
UDP Clients. The default UDP Port number is 601.
Source IP 1 ~ 8: Click in Source IP 1 ~ 8text box to specify IP addresses of Source UDP
Clients.
Restart Port: Check this option to restart the serial port on the Serial Device Server when you
click the “OK” button to finish UDP Setting.
Apply the above settings to all serial ports: Click this button to apply the above settings to
all serial ports.
5. Pair Connection
Step 1: Xport mode
Choose “Pair Connection” from the “Step 1: Xport mode”.
Fig 80. Pair Connection